>

Synthes rfna inventory - DESCRIPTION. LCP™ Proximal Tibia Plates merge conventional pl

TN-ADVANCED™ Tibial Nailing System. Product Codes: 03.043.002, 03.043.003, 03.043.0

WooCommerce is a powerful e-commerce platform that enables businesses to create an online store and sell products or services. One of the key aspects of running a successful WooCom...dps.jjkkpro.jpSpecialties Supported: Craniomaxillofacial (CMF), Foot & Ankle, Spine, Sports Medicine, Trauma & Extremities. Foot & Ankle, Spine, Sports Medicine, Trauma & ExtremitiesInventory Control Form TFN-ADVANCED™ Proximal Femoral Nailing System TFN-ADVANCEDTM System (TFNA), Long Nails, 11 mm distal diameter, sterile Right Part # Left Part # Length (mm) Femoral Neck Angle 04.037.120S 04.037.121S 300 125° 04.037.122S 04.037.123S 320 125° 04.037.124S 04.037.125S 340 125° 04.037.126S 04.037.127S …The Synthes MatrixRIB pre-contoured and straight plates are intended for tempo-rary reconstruction, if they are used as implant spanning gaps after resection of ribs and/or sternum. The Synthes MatrixRIB intramedullary splints (04.501.010, 04.501.011, 04.501.012) and the universal plate (04.501.009) are intended for rib fracture fixations andTN-ADVANCED™ Tibial Nailing System. Product Codes: 03.043.002, 03.043.003, 03.043.004... View More. PRODUCT CODES. DESCRIPTION. The TN-ADVANCED™ Tibial Nailing System (TNA) is an intramedullary nailing system for tibia fractures. This fixation system features design improvements to address previously unmet challenges with intramedullary ...The Large External Fixation System uses a modular construction to allow flexibility and a variety of forms of assembly to externally stabilize long bones, pelvic ring fractures, arthrodesis, and osteotomies. The system combines the Modular Knee Bridge and the Pelvic Frame. Product Specifications.DESCRIPTION. The Femoral Neck System (FNS) is a solution for femoral neck fractures where the growth plates have fused or cannot be crossed. Designed for improved angular stability 1 and rotational stability 2 with the intent to reduce reoperations related to fixation complications. Product Specifications. How to Use This Product.TN-ADVANCED™ Tibial Nailing System. Product Codes: 03.043.002, 03.043.003, 03.043.004... View More. PRODUCT CODES. DESCRIPTION. The TN-ADVANCED™ Tibial Nailing System (TNA) is an intramedullary nailing system for tibia fractures. This fixation system features design improvements to address previously unmet challenges …by the AO and DePuy Synthes and belong still to sur - geons basic armatorium used for fracture treatment, revision surgery and correction osteotomies. Due to their fixed-angle shape, successful application needs planning, concise orientation in all planes (AP and lateral views, rotation) and preparation of the channel for the blade. IntroductionUniversal Small Fragment System. Surgical Technique. 2.7 mm/3.5 mm Non-locking, Locking, and Variable Angle Locking Technology. Image intensifier control This description alone does not provide sufficient background for direct use of DePuy Synthes products. Instruction by a surgeon experienced in handling these products is highly recommended.of DePuy Synthes products. Instruction by a surgeon experienced in handling these products is highly recommended. Processing, Reprocessing, Care and Maintenance For general guidelines, function control and dismantling of multi-part instruments, as well as processing guidelines for implants, please contactInventory Control Form FRN-ADVANCED™ Piriformis Fossa Femoral Recon Nailing System Implants (continued) Available non sterile and sterile packed. Add “S” to catalog …Inventory Control Form 4.5 mm VA LCPTM Curved Condylar Plate System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. SS/VALCPCC/ICF/V2 04/22 Page 1 of 2 To order (USA): 800-523-0322In any business, effective inventory management is crucial for success. It involves the process of overseeing and controlling the flow of goods from the moment they are acquired to...Learn more about DePuy Synthes differentiated retrograde femoral nailing system RFN-ADVANCED™ at COA-AOC 2023. #RFNA #traumasurgery #AOtrauma #medtech…Synthes (USA) Products, LLC September 23, 2020 Keith Knapp RA Specialist 1301 Goshen Parkway West Chester, Pennsylvania 19380 USA Re: K201346 Trade/Device Name: DePuy Synthes Retrograde Femoral Nail Advanced System, DePuy Synthes Locking Screws for Medullary Nails, 5.0 mm Regulation Number: 21 CFR 888.302037mm 28mm 19mm 9.5mm 27mm 63mm 47.5mm 13.5mm 18.5mm SPEC SHEETS www.jnjmedicaldevices.com © DePuy Synthes 2021. All rights reserved. 164479-210113 02/21Inventory Control Form - Stainless Steel. View PDF. Inventory Control Form - Titanium. View PDF. Select all documents (2) Download Selected Items. -. DePuy Synthes 3.5 mm Periarticular Proximal Humerus Plates are indicated for fractures, fracture dislocations, osteotomies, and nonunions of the proximal humerus, particularly in osteopenic bone.According to the NAHB report for March, builders remained cautiously optimistic in April as limited resale inventory helped to increase demand in the new home market. According to ...Red fuming nitric acid (RFNA) is a storable oxidizer used as a rocket propellant.It consists of 84% nitric acid (H N O 3), 13% dinitrogen tetroxide (N 2 O 4) and 1–2% water. The color of red fuming nitric acid is due to the dinitrogen tetroxide, which breaks down partially to form nitrogen dioxide.The nitrogen dioxide dissolves until the liquid is saturated, and …4. DePuy Synthes TF10816 RFNA MDR Indication Language. 07/03/2022. Windchill Document #0000317918 5. DePuy Synthes RFNA Nail Inlay Axial Pullout Design Verification Report. 08/20/2020. Windchill Document #0000293479 6. DePuy Synthes RFN-Advanced System Locking Attachment Washer Rationale. 09/30/2020. Windchill …The LCP™ Wrist Fusion Set’s anatomic plate design combines LCP™ System technology distally in the metacarpal and proximally in the radial shaft. This technology allows for angular stable fixation and compression of the fusion site to ensure quality bone contact, even in osteopenic bone. Product Specifications.Inventory Control Form Titanium MatrixMIDFACE ™ Plating System 0.4 mm Malleable 04.503.081 38 mm x 45 mm 04.503.083 100 mm x 100 mm 04.503.086 Small arc 04.503.087 Large arc 04.503.090 30 mm diameter 04.503.091 70 mm diameter 04.503.092 100 mm diameter Titanium MatrixNEURO Contourable Mesh 03.503.368 Bending …3.5 mm VA LCP® Proximal Tibia Plate, Small Bend Available nonsterile or sterile-packed. Add “S” to catalog number to order sterile product. 02.127.210 4 holes, 87 mm, right 02.127.211 4 holes, 87 mm, left 02.127.220 6 holes, 117 mm, right 02.127.221 6 holes, 117 mm, left 02.127.230 8 holes, 147 mm, right 02.127.231 8 holes, 147 mm, left 02.127.240 …The Modular Mini Fragment LCP™ System is an instrument and implant module set intended for fixation of fractures, osteotomies, nonunions, replantations, and fusions of small bones and small bone fragments, particularly in osteopenic bone. Product Specifications. How to Use This Product.The LCP™ Wrist Fusion Set’s anatomic plate design combines LCP™ System technology distally in the metacarpal and proximally in the radial shaft. This technology allows for angular stable fixation and compression of the fusion site to ensure quality bone contact, even in osteopenic bone. Product Specifications.Consult Depuy Synthes's entire TFN-ADVANCED™ Proximal Femoral Nailing System (TFNA) catalogue on MedicalExpo. Page: 1/5SE_793148 AC page 2 / 7 Instructions for Use TFNA, 9 mm, long Right Left Length (mm) Femoral Neck Angle 04.037.916S 04.037.917S 260 125° 04.037.918S 04.037.919S 280 125°8 DePuy Synthes Surgical Technique MatrixMIDFACE™ Plate and Screw System Intended Uses, Indications, Contraindications Intended Use MatrixMIDFACE™ Plate and Screw System is intended. for use in trauma repair and reconstruction of the craniomaxillofacial skeleton. Indications. DePuy Synthes MatrixMIDFACE Plating System is intendedSYNTHES GMBH RFNA/ 12MM/ 320MM/ STANDARD BEND/ STER; ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES: Back to Search Results: Catalog Number 04.233.232S: Device Problem Adverse Event Without Identified Device or Use Problem (2993) ... Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, ...Whichever makes the synthes rfna inventory legally booking? As the world ditches in-office work, the completion out paperwork increasingly happens electronically. The synthes tna inventory isn’t an any different. Handling it using electronic tools is distinct free doing this inside the physical world.Synthes Flexible Reamer Set for Intramedullary Nails (150.060) Instrumentation Catalog # Description 351.05 Tissue Protector 351.15 Flexible Shaft Handle, Quick Coupling, Cannulated 351.717 Depth Gauge 351.719 Depth Gauge Extension Tube Holding Forceps 351.782 Holding Forceps 351.783 Removal Tool, for use with Medullary Reaming HeadsDESCRIPTION. The Femoral Neck System (FNS) is a solution for femoral neck fractures where the growth plates have fused or cannot be crossed. Designed for improved angular stability 1 and rotational stability 2 with the intent to reduce reoperations related to fixation complications. Product Specifications. How to Use This Product.Depuy Synthes GmbH OrthoKit® Rental Service Im Brunnenfeld 8 D-79224 Umkirch www.depuysynthes.com L004331S B01T01 ***End of document*** RFNA Sterilimplantate, Zusatzset Confidential Number: TV-SPEC-61433 Version: 1.0 Status: Effective Effective Date: 24 Feb 2022 (EST) This copy of the document was generated on 02 Mar 2022 …4 Surgical Technique ®• TFN-ADVANCED Proximal Femoral Nailing System (TFNA) The AO Principles of Fracture Management 1. Müller ME, Allgöwer M, Schneider R, …Farm clearing sales are an important aspect of the agricultural industry. These sales provide farmers with the opportunity to clear out excess inventory and equipment, while also a...About This Product. The TFN-ADVANCED Nailing System is a part of the Advanced Nailing System from DePuy Synthes and has features that allow surgeons to address proximal femur fractures. The system includes: Long Nails – Diameters: 9-12, & 14 mm. Lengths ranging from: 260 – 480 mm. Short Nails – Diameters: 9-12 mm.DePuy Synthes, RFN-Advanced System Locking Attachment Washer Rationale. 09/30/2020. Windchill Document #0000302371 9. DePuy Synthes, RFNA Nail/LAW Static Construct Design Verification Report. 04/28/2020. Windchill Document #0000293480* 10. DePuy Synthes, FRN Functional Design Requirements and Verification-Validation …Inventory Control Form RFN-ADVANCED™ Retrograde Femoral Nailing System Implants Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): RFN-ADVANCED™ System Ø 9 mm Diameter Nail, Sterile Standard Bend Periprosthetic Bend Length (mm) 04.233.916S 04.233.917S 160 mm 04.233.920S 04.233.921S 200 mm 04.233.924S 04.233.925S 240 mmTFN-ADVANCED™ Proximal Femoral Nailing System (TFNA) – Screw Only fi Surgical Technique 3 The AO Principles of Fracture Management 1. Müller ME, Allgöwer M, Schneider R, Willenegger H. Manual of Internal Fixation. 3rd ed. Berlin, Heidelberg New York: Springer 1991.Inventory Control Form RFN-ADVANCED™ Retrograde Femoral Nailing System Implants Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): RFN-ADVANCED™ System Ø 9 mm Diameter Nail, Sterile Standard Bend Periprosthetic Bend Length (mm) 04.233.916S 04.233.917S 160 mm 04.233.920S 04.233.921S 200 mm 04.233.924S 04.233.925S 240 mm5. DePuy Synthes ethnographic research on unmet needs in nailing. 1/20/2015. Windchill Document #0000306645 6. DePuy Synthes TNA Locking Polymer Rationale. 03/02/2021. Windchill Document #0000305648 7. DePuy Synthes Biomechanical test report for TN-Advanced Nail. 8/13/2020. Windchill Document #0000305118 8.Ensure the details you add to the Synthes Rafn Nail Inventory Control Form is updated and accurate. Add the date to the document using the Date function. Select the Sign button and make a signature. You can find 3 available alternatives; typing, drawing, or uploading one. Re-check each and every field has been filled in properly.02.130.150, 02.130.150S, 02.130.151... View More. PRODUCT CODES. DESCRIPTION. The Variable Angle Locking Hand System consists of 40 different basic and specialty plates, available in stainless steel and titanium, including fragment-specific plates designed for lateral and dorsal application in fracture repair and deformity correction.The MatrixRIB™ Fixation System offers stable fixation of normal and osteoporotic ribs combined with minimally invasive technique. The system consists of precontoured locking plates, locking screws, intramedullary splints, and custom instruments for the fixation and stabilization of the chest wall. 1. Get in Touch with a Sales Consultant.Complete Synthes Rafn Bolt Inventory Control Form 2020-2023 get use US Legal Forms. Easily fill out PDF clear, edit, and sign them. Save or instantly send your ready documents.Completing Synthes Rafn Arrest Inventory Control Form 2020-2024 online with US Legal Download. Easily fill out PDF blank, edit, and sign them. Saving or ... Tips on how to fill out, edit and sign Synthes rfna physical control web …About This Product. The Hindfoot Arthrodesis Nail permits a proper hindfoot alignment due to features such as: · Distal and talar locking options. · A spiral blade. · Lateral bend · End caps for improved stability2,3. Get in Touch with a Sales Consultant.SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J2210-I 10/12 Inventory Control Form 2.4 mm, 3.0 mm, 3.5 mm and 4.0 mm Cannulated Screws 2.4 mm Cannulated Screws Long Thread LENGTH LENGTH 211.810 10 mm 211.811 11 mm 211.812 12 mm 211.813 13 ...Inventory Control Form FRN-ADVANCED™ – Piriformis Fossa Femoral Recon Nailing System Implants Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): FRN-ADVANCED™ Femoral Recon Nail System, Piriformis Fossa, 9 mm distal diameter, sterile Right Part # Left Part # Length (mm) 04.033.928S 04.033.929S 280 04.033.930S 04.033.931S 300Synthes Tfna Inventory 0696-0502 Form Create a custom synthes tfna inventory 0744 that meets thy industry’s specifications. Get Download. Exhibit details Cover details. How ... Completing all kind of forms, including the synthes rfna inventory electronically seems enjoy a pretty easily process at first glance.Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants P J3266-K 3/11 Inventory Control Form DHS/DCS & DHS/DCS One-Step Insertion plvllllpklgulpu. † NT NT 4 16 mm 212.106 20 mm 212.108 4 4.x NT NT 44 4 4 16 mm 4 18 mm 4 20 mm 4 22 mm 44 4 4mm 4 28 mm 4 30 mm 4 32 mm ...Some advantages of inventory management include ensuring that a business does not spend money on unnecessary product orders and tracking which products are selling and which are no...of DePuy Synthes products. Instruction by a surgeon experienced in handling these products is highly recommended. Processing, Reprocessing, Care and Maintenance For general guidelines, function control and dismantling of multi-part instruments, as well as processing guidelines for implants, please contactSynthes guarantees the compatibil-ity of its different original implants and/or instruments. The product-specific instructions for use as described by Synthes must be followed. It is not advisable to mix Synthes products with those of different manufacturers, since designs, materials, mechanics, and construction are not harmonized.4 Surgical Technique ®• TFN-ADVANCED Proximal Femoral Nailing System (TFNA) The AO Principles of Fracture Management 1. Müller ME, Allgöwer M, Schneider R, Willenegger H. Manual of Internal Fixation. 3rd ed. Berlin, Heidelberg New York: Springer 1991.About This Product. The LCP™ Proximal Tibia Plates are indicated for fractures of the proximal tibia and treatment of nonunions, malunions, and osteopenic bone. They are available in the following options: 3.5 mm LCP Proximal Tibia Plate. 3.5 mm LCP Proximal Tibia Plate – Low Bend. 4.5 mm LCP Proximal Tibia Plate.SE_793149 AA page 2 / 5 Instructions for Use Retrograde Femoral Nail Advanced Devices in scope Retrograde Femoral Nail Advanced, 5 Degree Bend LengthThe Titanium Elastic Nail (TEN™) System consists of dedicated implants for stable fixation and instruments that facilitate handling. The nail tip facilitates nail insertion and sliding along the medullary canal 1,2 while nail marking allows direct visual control of the alignment of the nail tip in the medullary canal 1,2.In our relatively small sample of 8 patients treated forintramedullary nail breakdowns with revision of the TFNA implant, agreater than the 1-in-3 rate of re-rupture of the implant was served. Other variants of implants may be appropriate in revisionsetting, including other nails or conversion to arthroplasty.The R/AFN is a cannulated intramedullary nailing system for the treatment of fractures of the distal femur and/or diaphyseal fractures in which a retrograde approach is indicated. The R/AFN also enables fixation of fractures of the femoral shaft with an antegrade approach through the piriformis fossa. The R/AFN has a universal design for the ...Managing inventory efficiently is crucial for any business, regardless of its size or industry. It ensures that you have the right products in stock, minimizes stockouts and overst...Craniomaxillofacial Distraction (CMFD) System. The modular CMFD system offers a low-profile stable distraction construct without unintentional reversal combined with intraoperative flexibility and ease-of-use during application and removal. 1-3. Anti-reversal detent clip is contained within distractor body for a consistent, smooth profile that ...Inventory Control Form 3.5 mm Low Profile Pelvic System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale Canada. Please contact your sales consultant items approved for sale in 3.5LPPELVICICF001v2 08/22 3.5 mm Cortex Screws, self-tapping, with T15 StarDrive Recess Length 02.200.010Product Specifications. How to Use This Product. About This Product. The TFN-ADVANCED Nailing System is a part of the Advanced Nailing System from DePuy …Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Large External Fixator Patient Information: J2906-L 3/13 390.002 Large Multi-Pin Clamp, 6 position 390.003 Rod Attachment for Large Multi-Pin Clamp 390.004 Large Multi-Pin Clamp, 4 position 390.005 Large Combination Clamp4 DePuy Synthes Flexible Reamers for Intramedullary Nails Surgical Technique Hand Reamers, 6.0 mm, 7.0 mm, 8.0 mm • For use in medullary canals with an isthmus smaller than 8.0 mm • Use hand reamers incrementally to widen the medullary canal to 8.0 mm, before using the front-cutting 8.5 mm medullary reamer head under powerDESIGN EVIDENCE Results of the testing are summarized below, and comparison of 200 the nailing systems are displayed in Figure 6. 100 100 Pre-Fatigue Post-Fatigue Pre-Fatigue • The TFNA Nail mean slippage load in the pre-conditioning test Nail TFNA was 15% and 92% greater than the INTERTAN Nail and Gamma3 Nail, respectively; the TFNA Nail mean slippage load in the post-conditioning test was ...In today’s fast-paced business environment, effective inventory management is crucial for maintaining a smooth workflow and maximizing profitability. One key tool that can streamli...Synthes (USA) 1690 Russell Road Paoli, Pennsylvania 19301 Re: K042377 Trade/Device Name: Synthes (USA) Low Profile Reconstruction Plates Regulation Number: 21 CFR 888.3030 Regulation Name: Single/multiple component metallic bone fixation appliances and accessories Regulatory Class: I1 Product Code: HRS Dated: August 31, …If you sell products in the course of business, there comes a time when you can no longer afford to keep track of your inventory by hand. The process often becomes disorganized and...The purpose of this post-market registry is to monitor the clinical safety and performance (union rates and time to union) of two DePuy Synthes lower extremity shaft nails: RFN-Advanced Retrograde Femoral Nailing System (RFNA) and TN-Advanced Tibial Nailing System (TNA) in participants who have experienced femoral or tibial fractures, …This video features Tyson from Depuy Synthes teaching you the steps for insertion of a TFNA femoral nail.synthes.vo.llnwd.netInventory Control Form TFN-ADVANCED™ Proximal Femoral Nailing System Implants Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): TFN …Learn the Femoral shaft fracture: Fixation with Depuy-Synthes Expert retrograde/antegrade femoral nail (RAFN) surgical technique with step by step instructions on OrthOracle. Our e-learning platform contains high resolution images and a certified CME of the Femoral shaft fracture: Fixation with Depuy-Synthes Expert retrograde/antegrade femoral nail (RAFN) …Inventory Control Form Titanium MatrixMIDFACE ™ Plating System 0.4 mm Malleable 04.503.081 38 mm x 45 mm 04.503.083 100 mm x 100 mm 04.503.086 Small arc 04.503.087 Large arc 04.503.090 30 mm diameter 04.503.091 70 mm diameter 04.503.092 100 mm diameter Titanium MatrixNEURO Contourable Mesh 03.503.368 Bending …Orthopaedic Foot Instruments Surgical Technique DePuy Synthes 1 MR Information The Orthopaedic Foot Instruments have not been evaluated for safety and compatibility in the MR environment. It has not been tested for heating, migration or image artifact in the MR environment. The safety of the Orthopaedic FootSE_793148 AC page 2 / 7 Instructions for Use TFNA, 9 mm, long Right Left Length (mm) Femoral Neck Angle 04.037.916S 04.037.917S 260 125° 04.037.918S 04.037.919S 280 125°The new RFN-Advanced (RFN-A) Retrograde Femoral Nailing System was developed to address these issues. The Locking Attachment Washer (LAW) can be regarded as the most important innovation of the RFN-A System. The LAW concept allows to connect an anatomically shaped 6-hole plate (the locking attachment washer) at the lateral femoral epicondyle to ...In today’s fast-paced business environment, effective inventory management is crucial for the success of any organization. One of the primary reasons why inventory management is es...In today’s fast-paced business environment, effective inventory management is crucial for success. Properly managing your inventory not only ensures that you have the right product...Inventory Control Form Variable Angle Locking Hand System Titanium 1.3 mm Titanium Locking Plates* 04.130.150 Straight Plate, 6 holes 04.130.151 Straight Plate, 12 holes 04.130.152 T-Plate, 3 holes head, 5 holes shaft 04.130.153 Y-Plate, 3 holes head, 5 holes shaft 04.130.154 Phalangeal Base Plate, 2 holes head, 5 holes shaft*Part numbers with a trailing ‘S’ or ‘TS’ designate the sterile part number. Sterile part availability might be different depending on the country or region.About This Product. The TFN-ADVANCED Nailing System is a part of the Advanced Nailing System from DePuy Synthes and has features that allow surgeons to address proximal femur fractures. The system includes: Long Nails – Diameters: 9-12, & 14 mm. Lengths ranging from: 260 – 480 mm. Short Nails – Diameters: 9-12 mm.Synthes products supplied in a non-sterile condition must be cleaned and steam-sterilized prior to surgical use. Prior to cleaning, remove all original packag - ing. Prior to steam-sterilization, place the product in an approved wrap or contain - er. Follow the cleaning and sterilization instruction given by the Synthes brochureof DePuy Synthes products. Instruction by a surgeon experienced in handling these products is highly recommend, DePuy Synthes MatrixRIB straight plates are indicated for the fixation, stabilization and reconstru, Learn more about DePuy Synthes differentiated retrograde femoral nailing system RFN-ADVANCED, Jun 1, 2023 · Choose your Location. Last Updated Jun 1, 2023., Specialties Supported: Craniomaxillofacial (CMF), Foo, 4. DePuy Synthes TF10816 RFNA MDR Indication Language. 07/03/2022. Windc, About This Product. The LCP™ Proximal Tibia Plates, Some advantages of inventory management include ensuring that a , 3.5 mm VA LCP® Proximal Tibia Plate, Small Bend Available nons, Complete Synthes Rafn Nail Inventory Control Form 2020-2024 on, The Femoral Recon Nail System is an integrated nailing system des, Inventory Control Form - Stainless Steel. View PDF. Inventory , Consult Depuy Synthes's entire TFN-ADVANCED™ Proximal, The Variable Angle LCP™ Curved Condylar Plate is a distal femur, Inventory Control Form 3.5 mm Low Profile Pelvic Syste, This document shows the inventory of implants and instruments , Inventory Control Form Some devices in this form may not have been , Patient information: DePuy Synthes (USA) To order: (800) 227-6633 D.