>

Powerflex 523 parameter list - For more detailed information, see below for a link t

The Powerflex® 523 has greater functionality when compared to the PF4M. examples PowerFlex®

Note to stop drive before changing parameter t211 [Anlg In 0-10V Lo] removed. 3-14 New option 13, I/O Control, for parameter t221 [Relay Out Sel] added. 3-15 Fault description for F3 corrected. 4-3 Corrected Table B.F by adding the 0.75 kW (1.0 HP) and 1.5 kW (2.0 HP) ratings for the 22F-RF025-BL EMC line filter. B-4PowerFlex 700 Parameter Settings for Use with Adjustable Voltage Application with a Sine- wave Filter. This section describes the required parameter settings for using a …PowerFlex 523 Control I/O Wiring Block Diagram PowerFlex 525 Control I/O Wiring Block Diagram. 4 Rockwell Automation Publication 520-TD001D-EN-E - January 2014 ... • Create and save custom parameter groups using the CustomView™ tool. • Supports PowerFlex drives, Micro800™ controllers and PanelView™ component graphic terminals. ...PowerFlex 523 Catalog Number 25A. PowerFlex 525 Catalog Number 25B. This Quick Start guide summarizes the basic steps needed to install, start-up and program the PowerFlex 520-Series. Adjustable Frequency AC Drive. The information provided DOES NOT replace the User Manual and is intended for. qualified drive service personnel only.This release includes the following system features. New Parameter A573 [Mtr Options Cfg] Added to Improve Drive Performance in Some Applications (LGX00145380 and LGX00151724) System Feature Identified as of PowerFlex 525 Drives Firmware Revision 2.002. System Feature Identified as of PowerFlex 523 Drives Firmware Revision 3.001.May 2, 2019 · To add a VFD drive to Logix Designer, under I/O Configuration right click your network interface and select add module, then find the catalog number matching your drive and double click it. Now enter the drives name, IP address, rating, and other parameters. Click ' Ok .'. The drive should be added to the I/O Configuration. Drive as: drive, PowerFlex 4 or PowerFlex 4 Drive. Parameter numbers and names are shown in this format: The following words are used throughout the manual to describe an action: Similar PowerFlex 4 drive sizes are grouped into frame sizes to simplify spare parts ordering, dimensioning, etc. A cross reference of The PowerFlex 523 and 525 VFD offering has been expanded to include a PROFINET option card. The card connects drives to PROFINET to exchange data with the host controller easily. By installing a card in PowerFlex 520-Series drives through the main PROFINET device, you can: Control the drive through PROFINETNote: these parameter numbers are for PowerFlex 520s (523, 525, 527) drives and may differ for other PowerFlex drives. Check your drive’s manual for parameter numbers. ... (If prompted select the drive from the list of devices.) PowerFlex VFDs are very capable drives that with a little know-how can quickly be set up and commissioned. I …PowerFlex 525 Adjustable Frequency AC Drive 3 AppView Parameter Groups Fault and Diagnostic F Fault 4 Code F604 Fault 5 Code F605 Fault 6 Code F606 Fault 7 Code F607 Fault 8 Code F608 Fault 9 Code F609 Fault10 Code F610 Fault 1 Time-hr F611 Fault 2 Time-hr F612 Fault 3 Time-hr F613 Fault 4 Time-hr F614 Fault 5 Time-hr F615 Fault 6 Time-hr F616EtherNet/IP IP Address parameters are required at C128 to C140. Drive parameters / settings are assumed to be at default, unless otherwise stated. ... (Also same as PowerFlex 523) Para# Value Description P046 2 DigIn TrmBlk P047 5 0-10V Input P048 1 Embedded Keypad P049 1 DrivePot P050 4 Network Option P051 4 Network OptionThe Allen-Bradley® PowerFlex 520-Series of AC drives is the next generation of compact drives oering a variety of features and time-saving benets to help meet a wide range of global applications. PowerFlex® 523 AC drives are ideal for standalone machines and provide motor control for applications up to 11 kW/15 Hp.• Parameter names are shown in the format Parameter xx - [*]. The xx represents the parameter number. The * represents the parameter name. For example Parameter 01 - [Mode]. • Menu commands are shown in bold type face and follow the format Menu > Command. For example, if you read “Select File > Open,”PowerFlex 700 Parameter Settings for Use with Adjustable Voltage Application with a Sine- wave Filter. This section describes the required parameter settings for using a …For example, setting to “5” selects PowerFlex 4-Class drive Parameter 5 - [DC Bus Voltage] to be displayed. Default: 5 Minimum: 1 Type: Read/Write 06 [Large Disp Param] Selects a desired drive parameter to be displayed on the Large Format User Display screen. For example, setting to “1” selects PowerFlex 4-Class drive Parameter 1 ...Micro850 controllers and PowerFlex 523 drives are referenced throughout this Quick Start. Wherever a Micro850 controller is referenced, a Micro830 or Micro820 controller can also be used. Wherever a PowerFlex 523 drive is referenced, a PowerFlex 525, 4, 4M, 40, 40P, or 400 drive can also be used. Before You Begin PowerFlex 525 drives for network communication. The following conventions are used throughout this manual: • Parameter names are shown in the format axxx [*]. The a represents the parameter group. The xxx represents the parameter number. The * represents the parameter name— for example C175 [DSI I/O Cfg].the Main Control Board in PowerFlex 525 drives, and using it for network communication. The following conventions are used throughout this manual: • Parameter names are shown in the format axxx [*]. The a represents the parameter group. The xxx represents the parameter number. The * represents the parameter name— for example C141 [EN Rate Cfg]. The Powerflex 525 inverter is a series of Rockwell’s 520 inverter series, which is the new generation of Component inverters from Allen-Bradley. The Powerflex 520 inverter series was born to meet Rockwell’s Logix platform in common applications requiring inverters. ... PowerFlex 525 Parameters Setting. Basic parameters of the inverter to be ...PowerFlex 523 AC Drive 32 Rockwell Automation Publication PFLEX-SG002I-EN-P - May 2015 Additional Information PowerFlex 520-Series Technical Data, publication 520-TD001 PowerFlex 520-Series User Manual, publication 520-UM001 Catalog Number Explanation Product Selection 100…120V AC, Single-Phase Input, Three-Phase Output Drives, 50/60 Hz Drive ... Literature Library | Rockwell AutomationAllen-Bradley® PowerFlex® 523 AC Drive The Next Generation of Powerful Performance. Flexible Control. Innovative Modular Design PowerFlex 523 AC drives are made up of two modules that can be detached for simultaneous and independent wiring installation and software configuration. This innovative design allows you to begin mounting thePowerFlex 525 drives for network communication. The following conventions are used throughout this manual: • Parameter names are shown in the format axxx [*]. The a represents the parameter group. The xxx represents the parameter number. The * represents the parameter name— for example C175 [DSI I/O Cfg].Find Downloads. All PowerFlex Drives. Studio 5000 Logix Designer. Connected Components Workbench. Connected Components Workbench - Dev Ed. DriveTools SP. RSLogix 5000. show selections show by category show all versions.Our PowerFlex® 753 AC Drives are cost-effective and easy to use in general purpose applications requiring safety features. They come standard with built-in I/O, which is ideal for machine builders and system integrators who want to reduce engineering costs, deliver machines to market faster, and meet end user demand for more productive machines.Adjustable frequency ac drive (244 pages) Adapter Allen-Bradley PowerFlex 525 User Manual. Embedded ethernet/ip adapter (164 pages) Adapter Allen-Bradley PowerFlex 525 User Manual. Devicenet adapter catalog number: 25-comm-d (140 pages) Controller Allen-Bradley PowerFlex 525 Original Instructions Manual. Powerflex 520-series ac drive (48 pages) PowerHex 523 Contro b'O Wiring Blod Diagram Home Tools Variable Frequency . Instructor Notes Students can remove the cover from the PowerFlex523 and view the power wiring and also the control wiring terminal block. (LEARN LAB — The power input and output terminals are pre-wired on the PowerFlex523. 185 o' Outlook Today A Each hands- on …PowerFlex 523 AC Drive Rockwell Automation Publication PFLEX-SG002H-EN-P - February 2014 47 Additional Information PowerFlex 520Series Technical Data, publication 520TD001 PowerFlex 520Series User Manual, publication 520UM001 Catalog Number Explanation Product Selection 100…120V AC, SinglePhase Input, ThreePhase Output Drives, 50/60 Hz Drive ...PowerFlex 523 Catalog Number 25A. PowerFlex 525 Catalog Number 25B. This Quick Start guide summarizes the basic steps needed to install, start-up and program the PowerFlex 520-Series. Adjustable Frequency AC Drive. The information provided DOES NOT replace the User Manual and is intended for. qualified drive service personnel only.[Speed Reference3] default for PowerFlex 525. 16 “Positioning” (2) Referencing from . A558 [Positioning Mode] (1) Select this setting if using the optional PowerFlex 25-COMM-E2P, 25-COMM-D, or 25-COMM-P adapters as the speed reference. (2) Setting is specific to PowerFlex 525 drives only. P052 [Average kWh Cost] Related Parameter(s): b025PowerFlex 755 Parameter List and Uses. PowerFlex 755 is a variable-frequency AC drive designed by Allen-Bradley/Rockwell Automation, for ease of integration, high motor control performance, advanced safety and application flexibility. This high-power drive (power rating of up to 1500kW) builds on the common user experience and …Studio 5000 Logix Designer® software is a productivity win and your one-stop shop for managing the Allen‑Bradley Logix 5000™ family of controllers and related control system. Premier integration of Studio 5000 Logix Designer and PowerFlex® Drives. Reduces drive system development time by as much as 70%.Jan 11, 2021 · The jumper J10 with PowerFlex 525 drive, or J13 with PowerFlex 523 Series B drive, configures the Analog Output; install the jumper on the top 2 pins for a 0/4-20mA output or the bottom 2 pins for 0-10V output. Note: The Analog Output Select jumper J10, or J13, must be set to match the analog output signal mode set in Parameter t088 [Analog Out ... PowerFlex 753 and PowerFlex 755 Pre-engineered FasTrac Packaged Drives e (cont’d) Output amps, Hp ratings @ 600V AC Input (1) (1) 600V AC rating is only available in Canada. Code Amps ND Hp HD Hp Frame Size 1P7 1.7 1 3 2P7 2.7 213 3P9 3.9 323 6P1 6.1 533 009 9 7.5 5 3 011 11 10 7.5 3 017 171510 3 022 222015 3 027 272520 4 032 …8 Rockwell Automation Publication PFLEX-AT001M-EN-P - October 2022 Chapter 1 Understanding How Dynamic Braking Works Dynamic Brake Components A Dynamic Brake consists of a Chopper (the chopper transistor and related control components are built into PowerFlex® drives) and a Dynamic Brake Resistor. Figure 1 shows a simplified …Figure 1 - DriveExecutive Parameter List, Parameter Access Level. Figure 2 ... 523 [Bus Utilization]. This value sets the drive output voltage limit as a.Step 2: Determining Where the IP Address is Set – Once you have found the “C”, press Enter. Then using the up/down arrows, scroll through to find C128. The C128 value tells you how the IP address is set. It will either be set by “BootP” or by “Parameters”. If the IP address is set by BootP, the value displayed will be a 2.PowerFlex Architecture Class HIM, 20-HIM-A5, has an LCD and a Programmer Only Keypad. It is used with Powerflex 70, 700, 700H, 700S and 700L AC drives. It can be directly mounted on a drive or used as a hand-held device. PowerFlex 7-class Remote HIMs:20-HIM-C3 and 20-HIM-C5 are PowerFlex 7-class Remote HIMs. …Common PowerFlex 523 parameters Set Motor Nameplate data (“P” file) P031: motor Voltage P034: motor FLA P032: motor Hz (50 & 60) P035: # motor poles (1800rpm = 2) P033: overload current P036: motor rpm P037: motor HP Set basic appl data (“P” file)8 Rockwell Automation Publication PFLEX-AT001M-EN-P - October 2022 Chapter 1 Understanding How Dynamic Braking Works Dynamic Brake Components A Dynamic Brake consists of a Chopper (the chopper transistor and related control components are built into PowerFlex® drives) and a Dynamic Brake Resistor. Figure 1 shows a simplified …Allen-Bradley PowerFlex 523 Original Instructions Manual (48 pages) PowerFlex 520-Series AC Drive. Brand: Allen-Bradley | Category: Controller | Size: 4.21 MB. Table of Contents. Table of Contents. 1. For more detailed information, see below for a link to the PowerFlex 525 troubleshooting guide. Fault Name/Description/Action. F000 No Fault. No fault present. -----. F002 Auxiliary Input. External trip (Auxiliary) input. • Check remote wiring. • Verify communications programming for intentional fault.The Allen-Bradley® PowerFlex 520-Series of AC drives is the next generation of compact drives off ering a variety of features and time-saving benefi ts to help meet a wide range of global applications. PowerFlex® 523 AC drives are ideal for standalone machines and provide motor control for applications up to 11 kW/15 Hp. PowerFlex 753 and PowerFlex 755 Pre-engineered FasTrac Packaged Drives e (cont’d) Output amps, Hp ratings @ 600V AC Input (1) (1) 600V AC rating is only available in Canada. Code Amps ND Hp HD Hp Frame Size 1P7 1.7 1 3 2P7 2.7 213 3P9 3.9 323 6P1 6.1 533 009 9 7.5 5 3 011 11 10 7.5 3 017 171510 3 022 222015 3 027 272520 4 032 323025 4 041 ...In addition, they offer USB programming, application-specific configuration, and flexible mounting options. PowerFlex 523 AC drives offer a power rating of 0.2...22 kW (0.25...30 Hp) with global voltage classes of 100...600V. They support a wide range of motor control, offer a compact footprint, and operate at temperatures as high as 70 °C ... PowerFlex 523 AC drives are made up of two modules that can be detached for simultaneous and independent wiring installation and software configuration. This innovative design allows you to begin mounting the ... Application-specific parameter tools such AppView and CustomView configuration can help streamline drive setup. You can alsoPowerFlex 755 Parameter List and Uses. PowerFlex 755 is a variable-frequency AC drive designed by Allen-Bradley/Rockwell Automation, for ease of integration, high motor control performance, advanced safety and application flexibility. This high-power drive (power rating of up to 1500kW) builds on the common user experience and application ...This release includes the following system features. New Parameter A573 [Mtr Options Cfg] Added to Improve Drive Performance in Some Applications (LGX00145380 and LGX00151724) System Feature Identified as of PowerFlex 525 Drives Firmware Revision 2.002. System Feature Identified as of PowerFlex 523 Drives Firmware Revision 3.001.Oct 26, 2021 · The full list of the DeviceNet Adaptor Card’s features follows, as pulled from the card’s User Manual, publication #520COM-UM002A-EN-E, dated April 2013: Mounting onto a PowerFlex 525 [and 523] Control Module back cover for installation into the drive. It receives the required power from the drive and from the DeviceNet network. PowerFlex 753 and PowerFlex 755 Pre-engineered FasTrac Packaged Drives e (cont’d) Output amps, Hp ratings @ 600V AC Input (1) (1) 600V AC rating is only available in Canada. Code Amps ND Hp HD Hp Frame Size 1P7 1.7 1 3 2P7 2.7 213 3P9 3.9 323 6P1 6.1 533 009 9 7.5 5 3 011 11 10 7.5 3 017 171510 3 022 222015 3 027 272520 4 032 323025 4 041 ...Allen Bradley Power Flex 525 “Basic Setup”. The Powerflex 525 inverter is a series of Rockwell’s 520 inverter series, which is the new generation of Component inverters from Allen-Bradley. The Powerflex 520 inverter series was born to meet Rockwell’s Logix platform in common applications requiring inverters. PowerFlex 4 Adjustable Frequency AC Drive FRN 6.xx This Quick Start guide summarizes the basic steps needed to install, start-up and program the PowerFlex 4 Adjustable Frequency AC Drive. The information provided Does Not replace the User Manual and is intended for qualified drive service personnel only. Allen-Bradley PowerFlex 523 Manual Online: Advanced Program Group Parameters. See the PowerFlex 520-Series Adjustable Frequency AC Drive User Manual, publication descriptions of the parameters listed here, as well as the full list of available parameters. The Powerflex® 523 has greater functionality when compared to the PF4M. examples PowerFlex® 4M 415 V AC Input Heavy duty (kW) Output current (A) Dimensions Watts Loss (W) ... • Application specific parameter groups with possibility of creating customer user parameter sets, part of the standard menu structure ...The PowerFlex 527 drive allows for the selection of 1/2 DC Bus operation, for use in critical applications where continued drive output is desired even in the event of brown out or low voltage conditions. The PowerFlex 527 drive also supports enhanced inertia ride-through for additional low voltage mitigation.Posts: 91. F004 is an Under Voltage fault that occurs when you power off the PowerFlex. Edit: I have not seen the F004 fault when the PowerFlex was running. It could happen when the incoming voltage drops below the minimum voltage level. Last edited by swimmy67; September 28th, 2015 at 07:59 AM.The PowerFlex 523 and 525 VFD offering has been expanded to include a PROFINET option card. The card connects drives to PROFINET to exchange data with the host controller easily. By installing a card in PowerFlex 520-Series drives through the main PROFINET device, you can: Control the drive through PROFINETFor more detailed information, see below for a link to the PowerFlex 525 troubleshooting guide. Fault Name/Description/Action. F000 No Fault. No fault present. -----. F002 Auxiliary Input. External trip (Auxiliary) input. • Check remote wiring. • Verify communications programming for intentional fault.Zero Stacking™ Drives for ambient temperatures up to 40 °C (104 °F) Drive overload protection and ramp regulation. Configuration and programming via integral LCD keypad, remote keypad, or software. Premier Integration with PowerFlex AC drives uses the Logix control platform to simplify parameter and tag programming and reduces development time.PowerFlex 523 AC Drive 32 Rockwell Automation Publication PFLEX-SG002I-EN-P - May 2015 Additional Information PowerFlex 520-Series Technical Data, publication 520-TD001 PowerFlex 520-Series User Manual, publication 520-UM001 Catalog Number Explanation Product Selection 100…120V AC, Single-Phase Input, Three-Phase Output Drives, 50/60 Hz Drive ... Adjustable frequency ac drive (244 pages) Adapter Allen-Bradley PowerFlex 525 User Manual. Embedded ethernet/ip adapter (164 pages) Adapter Allen-Bradley PowerFlex 525 User Manual. Devicenet adapter catalog number: 25-comm-d (140 pages) Controller Allen-Bradley PowerFlex 525 Original Instructions Manual. Powerflex 520-series ac drive (48 pages)on Parameter List, will open the parameter list and allow the values of parameters to be seen or changed if shown in white. You can Close each Parameter List after you have viewed them. As all the parameters for each drive is visible within RSLogix5000, saving the RSLogix5000 project also saves all the drive parameters.3 “Power Reset” Resets only power parameters. Can be used when you swap power modules. 4 “Module Reset” (1) (2) (1) Setting is available in PowerFlex 525 FRN 5.xxx and later. (2) Setting is available in PowerFlex 523 FRN 3.xxx and later. Power cycle of the drive, NO parameters are reset. P053 [Reset to Defalts] Load Default = 2 (Factory ...Allen Bradley Power Flex 525 “Basic Setup”. The Powerflex 525 inverter is a series of Rockwell’s 520 inverter series, which is the new generation of Component inverters from Allen-Bradley. The Powerflex 520 inverter series was born to meet Rockwell’s Logix platform in common applications requiring inverters. 3 “Power Reset” Resets only power parameters. Can be used when you swap power modules. 4 “Module Reset” (1) (2) (1) Setting is available in PowerFlex 525 FRN 5.xxx and later. (2) Setting is available in PowerFlex 523 FRN 3.xxx and later. Power cycle of the drive, NO parameters are reset. P053 [Reset to Defalts] Load Default = 2 (Factory ...The PowerFlex 523 and 525 families can be programmed via FREE Connected Components Workbench. Without having a Rockwell/Allen-Bradley PLC program to reference (which would give you status of all drive internal parameters), you should download and install CCW (requires a FREE Rockwell user account).(PowerFlex 523 drives support one, PowerFlex 525 drives support two) Packaging and Mounting • Installation can be quick and easy using the DIN rail mounting feature on A, B, and C frame drives. Panel mounting is also available, providing added flexibility. • Zero Stacking is allowed for ambient temperatures up to 45 °C, saving valuable ...Page 11 Aotewell Ltd www.aotewell.com Industry Automation PowerFlex 520-Series AC Drive Specifications Control Outputs Specifications PowerFlex 523 PowerFlex 525 Relay Quantity: (1) Programmable Form C (2) 1 Programmable Form A and 1 Programmable Form B Specification Resistive Rating: 3.0 A @ 30V DC, 3.0 A @ 125V, 3.0 A @ 240V AC …to user manuals for specifi c parameter and tag information. All PowerFlex drives on EtherNet/IP or ControlNet are able to take advantage of these add-on profi les. In addition, Automatic Device Confi guration (ADC) support for the PowerFlex 753*, PowerFlex 755, PowerFlex 523* and PowerFlex 525 AC drives helps reduce downtime.Video. Automation. In this video you'll be shown how to use Rockwell Automation's Connected Components Workbench software to set up your PowerFlex 523 Drive. Included in the video: beginning a project, using startup wizards, viewing parameters by application and creating custom groups, viewing non-default parameters, returning your drive to ...The PowerFlex 527 drive allows for the selection of 1/2 DC Bus operation, for use in critical applications where continued drive output is desired even in the event of brown out or low voltage conditions. The PowerFlex 527 drive also supports enhanced inertia ride-through for additional low voltage mitigation.It is connected via a ribbon cable and plugs into the drive. The PowerFlex 523 drive has an add-on module (25-COMM-E2P) dual-port adapter. PowerFlex 523 drives now have direct access to parameters inside the drive for communication (e.g., IP address, subnet masking, and gateway configuration if used outside the facility with gateway). PowerFlex 400 AC Drives 22 PowerFlex 523 AC Drives 26 PowerFlex 525 AC Drives 29 PowerFlex 527 AC Drives 32 PowerFlex 755TS AC Drives 35 PowerFlex 755TL/TR AC Drives 42 PowerFlex 753 AC Drives 51 PowerFlex 755 AC Drives 56 PowerFlex 70 AC Drives 61 PowerFlex 700 AC Drive 64 PowerFlex DC Drives 65 The PowerFlex DC Field Controller 67 EtherNet/IP Interface. The P_PF52x can also control and monitor a PowerFlex 525 variable-frequency drive with embedded or optional add-on EtherNet/IP Interface. Guidelines Use this instruction to monitor and control a motor that uses an Allen-Bradley® PowerFlex 523 or PowerFlex 525 variable frequency drive interfaced via EtherNet/IP.Oct 20, 2014 · This is a guide for setting up the Rockwell Automation standalone PowerFlex 523 Drive. It has the capability to be configured using the buttons on the front ... Description: The Allen-Bradley 25A-D010N104 PowerFlex 523 adjustable frequency AC drive. This drive features an input voltage range of 380-480VAC, 3-phase and delivers output voltage of 0-460VAC, 3-Phase, with rated Current of 10.5 A and Power of 4 kW (5 HP) for both normal and heavy duty operation. It has an integral RS485 communication …PowerFlex 523 Adjustable Frequency AC Drive Catalog Number 25A Summary of Changes This publication contains new or updated information. Changes throughout this revision are marked by change bars, as shown to the left of this paragraph. Mounting Considerations • Mount the drive upright on a flat, vertical, and level surface.This product was certified with the above certifications as of 2023-09-22. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries. PowerFlex 525 0.75kW (1Hp) AC Drive. Learn how to install, configure and operate the PowerFlex 525 AC D, PowerFlex 525 drives, which offer a power rating of 0, Adjustable frequency ac drive (244 pages) Adapter Allen-Bradley Pow, EtherNet/IP Interface. The P_PF52x can also control and monitor a PowerFlex 525 variable-, Powerflex Architecture-class 7-series; ID: QA28250 | Access Levels: Everyone. PowerFlex 750 Series: Parameter list in , PowerFlex 40 Adjustable Frequency AC Drive FRN 5.xx - 6.xx This Quick Start , PowerFlex 525 drives support the RS485 (DSI) protocol to allow efficient operation with Rockwe, The PowerFlex 523 and 525 VFD offering has been expanded to, Allen-Bradley PowerFlex 523 Manual Online: Basic Display Group Pa, Controller Allen-Bradley PowerFlex 523 Quick Start Manual. Powerflex , Posts: 91. F004 is an Under Voltage fault that occurs when you power, Page 33 ATTENTION: Due to its control circuitry difference from the, Webflow, For example, setting to “5” selects PowerFlex 4-Class drive Parame, The PowerFlex 523 and 525 VFD offering has been expanded to in, Powerflex Architecture-class 7-series; ID: QA28250 | Access L, See Program Group Parameters Programming and Parameters on , PowerFlex 523 AC drives are made up of two modules that can be detache.