Eaton xy shifter problems

10 k-7061 shift lever hsg kit 241075 ,4302711 ,a - 6439 1 aluminum hou

Volvo Eaton 10 Ultrashift VALR Range Low Actuator XY shifter FIXMID 130 SID 40 FMI 5 2007 Volvo vhd780 volvo vnl780 Transmission ECU Range low actuator Follo... If you need to service or repair your Eaton Fuller HD FR/FRO transmissions, you can download this service manual that provides detailed instructions and diagrams. You will learn how to perform in-vehicle service procedures and transmission overhaul, as well as how to identify parts and specifications.Step A: XY Shifter Identification Pre-April 2009 built XY’s can be identified by the painted motor and end caps, and are not affected by the recent issues. These XY’s should NOT be replaced under this program. Continue to Step V. XY’s built April 2009 through September 15, 2010 can be identified by the chromate (unpainted) motor and end caps.

Did you know?

Xy-shifter Gear Select repair. Transcript. Follow along using the transcript. Show transcript. Erinson Duran. 589 subscribers. Videos. About. Xy-shifter Gear Select repair.Volvo VNL , Cummins ISX, Eaton Fuller 10 Speed Autoshift. I was having an issue sometimes with the tranny downshifting from 7 to 6. So today I replaced the xy shifter and the wiring harness for the xy … read moreFault Code 51 is set when the TECU has detected either an electrical failure of the X-Y Rail Position Sensor circuit or a mechanical failure within the X-Y Shifter. Detection The TECU monitors both the 5-volt X-Y Rail Position Sensor supply and the return voltage signal from the X-Y Rail Position Sensor.Volvo VNL , Cummins ISX, Eaton Fuller 10 Speed Autoshift. I was having an issue sometimes with the tranny downshifting from 7 to 6. So today I replaced the xy shifter and the wiring harness for the xy … read more2 04-28-2018, 04:24 AM. (04-28-2018, 02:55 AM)IROC Wrote: 2007 Eaton 13 speed Ultrashift Gen III. Vehicle was towed to the shop. Transmission stuck in gear and when driver shut engine off, it wouldn't go back to neutral. Managed to get it started after sitting for tow truck but could not drive it. Only inactive code was for the XY shifter. 1 07-23-2020, 06:32 AM. Hi guys need some input. I'm working on a 2012 cascadia with a dd15 and a ultrashift (smartshift) transmission. Truck will not shift into gear. I have no fault code in Eaton serviceranger or on the engine in dddl. No abs codes ether. When I release the brakes and shift into R or D you can hear the transmission engage ...Posted 3/29/2013 18:40 (#3000467 - in reply to #3000402) Subject: Re: Eaton Fuller Ultra shift problems. Traverse City MI. Carry a broom stick with you. The shifter motors will sometimes hang up and need to be tapped on with the broom stick.This could be a faulty XY shifter, am electrical issue or internal damage inside of the transmission. The 36 fault code is a communication issue between the ECM and the transmission ... Having an issue with Kenworth t680 eaton 10 speed automatic transmission VIN is ***** Won't switch to the gear it says N and F These codes came on SPN 788 ...Find many great new & used options and get the best deals for Eaton Fuller Transmission Parts Gen Generation 2 XY Shifter at the best online prices at eBay! Free shipping for many products!Electrical and Industrial | Power management solutions | EatonSubject: Gen 3 XY Shifter Updates. Document Number: TAIB-0866. Date: November 15, 2017 Updated: Issue Description: Four updates have been recently implemented on the Gen 3 XY shifter assemblies to improve reliability/accuracy and reduce oil leaks. XY Housings • Current sand-cast housings 4307180 and 4308016 have been …2 04-28-2018, 04:24 AM. (04-28-2018, 02:55 AM)IROC Wrote: 2007 Eaton 13 speed Ultrashift Gen III. Vehicle was towed to the shop. Transmission stuck in gear and when driver shut engine off, it wouldn't go back to neutral. Managed to get it started after sitting for tow truck but could not drive it. Only inactive code was for the XY shifter. Remove the cap on the end. You will need to drain the transmission fluid and replace all the gears in the end cap if damaged hopefully they are not and you can just tighten up the nut. What happens is a nut comes loose and backs off the pressure on the bearings and you loose 5th. I removed the entire transmission and opened it up.to shift (see Note *). † System holds current gear unless otherwise prompted by using up / down-shift buttons, except for the “Transmission Override” condi-tions noted below. Note: Multiple gear upshifts and downshifts may be allowed when the shift buttons are pushed multiple times (Each button push equals one gear change request). K Purpose: Visually identify if the shift lever is an Eaton built shift lever or an OEM built shift lever. 1. Is vehicle equipped with an Eaton supplied Shift Lever or an OEM supplied Shift Lever. 1. Key off. 2. Disconnect negative battery cable. • If Eaton Cobra Lever, go to Step L. 3. Disconnect 38-way Vehicle Harness from TECU.When my old carrier was running International Junkstars we had the exact problem you desccribe. XY shifters would crap out at about 50,000 miles or so. Whenever I went to a terminal it seemed like every other truck in the shop was an automatic Cornbinder.Posted 3/29/2013 18:40 (#3000467 - in reply to #3000402) Subject: Re: Eaton Fuller Ultra shift problems. Traverse City MI. Carry a broom stick with you. The shifter motors will sometimes hang up and need to be tapped on with the broom stick.7 set 2018 ... Eaton's Ultrashift Plus 18-speed transmission is arguably the simplest ... X-Y shifter. In terms of reliability, the main components have a ...Position X-Y Shifter on the Shift Bar Housing. Using a 9/16” socket, install mounting cap screws and tighten in a cross pattern as follows: Tighten to 30–35 lb-ft (45–60 N•m).Transmission Shift Console Permits selection of clutch engagement options by shifter position to Mode Configuration provide optimum mobility for the vehicle application – including Standard, Creep Mode, Blended Pedal, and Urge to Move. Vocational Shift Response The shift response setting controls the torque ramp-down before a shift

2 03-14-2015, 08:13 PM. (03-14-2015, 07:53 PM)ddser60 Wrote: RTO-16910C-AS3 the box is 10 speed 3 pedal auto shift on Freightliner Columbia 2007. The transmission will stick in gear and can't shift to neutral. After a few attempts will go to neutral, then can't go into gear. I noticed that once in gear, will shift up and down without problems.K4223RX Eaton Fuller Gen 3 XY HD Shifter. 5.0 1 product rating. kahgotruckparts(8086) 100% positive feedback; Price: ... KIT, GEN 3 X-Y SHIFTER, REMAN HEAVY DUTY. FUL ...Xy shifter is about $600, you can change it yourself. it does have its own computer. The first thing I did was get under and unplug every connector, put in some dielectric grease, then plugged em all back up. Knock on wood I've never had any issues with that in 3 yrs I've had the truck. The rest of the transmission is the same as a regular …Here's the truck: 2007 Century S/T w/ a CAT C-15 pushing an Eaton 10-speed SmartShift automatic tranny. Here's the issue: You apply the service brake and drop the truck into D and the truck goes into gear the first time, no problem.UltraShift PLUS Service Manual - Eaton CumminsThis pdf document provides detailed instructions on how to service and troubleshoot the UltraShift PLUS automated manual transmission, which is designed for various vocational applications. Learn how to diagnose, repair, and maintain your UltraShift PLUS transmission with this comprehensive guide.

Sep 25, 2015 · Well-Known Member. Nov 8, 2015. #8. Jefro, just had problem w/ Ultrashift, took to Kw in Van Buren, Ar, excellent mechanic [Danny} discovered chaffed wire going to tranny controls, took $2.30 roll of tape, spend $974.00. Expensive trip but solved problem and truck is back working! UltraShift PLUS Service Manual - Eaton CumminsThis pdf document provides detailed instructions on how to service and troubleshoot the UltraShift PLUS automated manual transmission, which is designed for various vocational applications. Learn how to diagnose, repair, and maintain your UltraShift PLUS transmission with this comprehensive guide.Feb 4, 2015 · Feb 4, 2015. #2. MattM750 said: Hey everyone, So I am new to this forum and don't know much about semis, but my father doesn't know much about computers. Anyways, he has a 2010 Kenworth T800 day cab with the automatic Eaton Fuller transmission. When he tries to shift it it becomes stuck in 2nd gear and won't shift any higher up. …

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. Calibration of an X-Y shifter is accomplished under the co. Possible cause: I can't remember the sequence exactly but if you search the eaton website faul.

Well-Known Member. Nov 8, 2015. #8. Jefro, just had problem w/ Ultrashift, took to Kw in Van Buren, Ar, excellent mechanic [Danny} discovered chaffed wire going to tranny controls, took $2.30 roll of tape, spend $974.00. Expensive trip but solved problem and truck is back working!Sounds like the XY shifter going bad on the transmission. When it starts acting up, one of the things it does is what you are describing. I've had them get stuck in gear, not shift, not shift all the gears, and not downshift. ... Hello, I have an eaton autoshift gen 2 having problems with it shifting, ...

Feb 20, 2018 · Paccar Inc. is recalling approximately 1,938 2017-2018 Kenworth T680 and T880 trucks as well as Peterbilt 567 and 579 trucks equipped with an automated Eaton UltraShift Plus or Eaton Advantage ... i have 2016 International Pro-star with Eaton Ultra-shift 16 speed. all in sudden it developed a problem it wont go past 10th gear. it has fault light on i checked the fault it is fault #13 and fault #36 according to Eaton it has something to do with J protocol.

S2745R Fuller Reman XY Shifter Assembly. $1,751.47. Add to Cart. Quick 1. Fault Code P0700: Transmission Control System Malfunction. The transmission control system of the Kenworth T680 truck is responsible for managing the shift points and torque converter lock-up of the automatic transmission. It monitors engine operation, vehicle speed, and other parameters to determine when to smoothly engage … Eaton Fuller Transmission Gen 2 Xy ShiftThe Ultrashift problems are hanging between gears (programming prob Note: If the Shift Finger is not properly aligned, the X-Y Shifter will not fit properly at its mounting location. Clean and remove old gasket material from Shift Bar Housing. Then, install new gasket on the Shift Bar Housing.Mar 31, 2015 · Truck Repair. I have a 2007 Freightliner Columbia, ultra shift. Has problems…. Answered in 32 minutes by: The dealers use a program called Eaton Service Ranger which will pull the trouble codes and assist in doing the various pinpoints that are needed to diagnose the fault. What makes the F code so bad is the fact that it just mean failure. If you need to service or repair your Eaton Fuller HD FR/F 3 lug 2023 ... Eaton Fuller XY Shifter Assembly - Sold. This product is currently out of stock and unavailable. Stock: 3088-S2745R Category: Transmissions ...What are the common problems with Eaton Fuller 10 speed transmission? Some of the most common problems with Eaton Fuller 10 speed transmission are: Vibration and shaking; Loud and unusual noise; Gear slippage Difficulty shifting gears; Transmission overheating; Why is Vibration and shaking a problem with Eaton Fuller transmissions? Eaton Inforanger. Electronic Parts Catalog. SearcVerify Shift Blocks are tight to the rails and thereTake a detail look at xy shifter automatic Eaton P We had calibrated the new XY shifter several times during installation as per Eaton instructions, so we removed the XY shifter to verify correct operation in the cycle. it went side to side and forward and back, than to center. Reinstalled the XY shifter, re-calibrated, and still the same problem. Eaton Reman XY Shifter S2745R. Be the first to w Find many great new & used options and get the best deals for Eaton Fuller Autoshift XY Shifter - A-7034 C7r674 at the best online prices at eBay! Free shipping for many products! ... OEM Eaton Fuller 18 Speed Transmission Shift Knob Medallion Pattern 5586114. 4.7 out of 5 stars based on 7 product ratings (7) $18.50 NewTampa. (813) 685-6100. Shop New XY SHIFTER (GEN3) HEAVY DUTY for sale online from Weller Truck. Visit our site today for new and remanufactured truck parts and equipment. Apr 18, 2022 · Good morning, thanks for asking, I’m in the pr[Shift solenoid failure; Transmission fluid leakage; LoEaton Fuller Ultra Shift ... I have no issues shifting at all o Eaton Cummins Automated Transmission Technologies has a broad portfolio of transmissions to help you get the job done. By answering a short series of questions about your truck and your route, we'll give you a couple of recommendations for heavy-duty automated transmissions that best fit your fleet's unique needs. Take me to the selector.